Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipment’s from high and low voltage.
Specially designed for sensitive loads Servo Oil Cooled - 3phase series provides Output voltage set ( 210-245V), Output Low Voltage Cutoff Output High Voltage Cutoff, Input Low on LCD Display Input High on LCD Display, Sensitivity / Regulation, Auto Restart Time, On & Off Delay Time Over Load Cutoff, CT full scale, Over load Cutoff Time On & Off Delay Time, Display Scrolling – Auto / Manual Start / Stop Buttons
Capacity | : KVA -3PH Domestic / Industrial Model |
---|---|
Model | : PED19MODEL |
Input Voltage Range | : 320--460V AC / 360--470V AC / 340--480V AC 3phase |
Output Voltage | : 400/415V AC 3PH - 230/240V AC 1PH |
No. of Phases | : Three / Single Phases |
Speed of Correction | : 35V per Second |
Line Frequency | : 47-53Hz |
Output Voltage Regulation | : +2% |
Type of Cooling | : OIL COOLED Natural Air Cooling |
Type | : Unbalanced Supply and Load Conditions |
Efficiency | : 97% |
Model | : Industrial / Domestic Roboust |
Wave Form Distortion | : True Reproduction of Input Wave Form |
Effect of Load Power Factor | : Nil |
Ambient Temperature | : 0-45ºC |
Duty Cycle | : Continuous |
Indications on Each Phase | : DISPLAYED ON LCD DIAPLAY R,Y,B,N INPUT, OUTPUT, CURRENT, FREQUENCY 1PH/3PH |
Metering | : LCD Display to Read Input and Output Voltage. 1Ph/3ph |
Display | : LCD / Digital of Input and out put Voltages, reasons Display Features also be provided over load frequency mismatch, low voltage high voltage |
Regulation Time | : Less than 60V per Second Complete One Operating Cycle |
Operating Temperature | : -10 to 55 Deggree Centigrade |
Over Voltage Protection | : Auto Trip Features Enabled in the Event of Input Voltage |
Features and Protections | : Protection Class Minimum IP 20 and Overload and Short Circuit Protections Enabled for Internal with Circuit Breaker and MCB/ Contactor. |
Controls Enabled | : Auto Manual Control, Over Load Trip Relay, Output Low/High Cutt off , Output Hight Frequency Cut off |
Indications | : Mains ON indications, Out put On Indication, Input Fail Indications |
Metering | : We can read Voltages, Phase to Phase – Phase to Neutral, Current of each Phase Shown on LCD Display, Alram is Enabled, with Buzzer |
ERROR Log | : LCD Diplay Shows The Error Log With Alarm For. Eg. R phase Input Voltage High – then Display Contneous Showing On Screen R phase I/P volt Hight. 100 Alarms messages Troubles to be Recorded in the Servo Stablizer with Alram Log History With Date Time Stored the Stablizer |
Neutral Missing Protections | : Servo Stablizer Stop the Work When Neutal Found Missing |
Earth Neutral Protection | : If Earth to Neutral Voltage Increased then Servo Stablizer Output will be Switched OFF, and Indication Alrarm Shows. (Both Extra Features Neutral and Neutral Earth Protections) if Required then Enables in Program Single Phase Preventer is Disabled in Domestic Model Individual Phase Cut off. |